CORROSION - SHAFTS - MEGA YACHT

Two shafts (6m length, 14cm diameter) from mega-yachts suffered from corrosion. Following proper preparation the ENECON engineers in Greece built & restored the shafts to their original shape/condition using ENECON DurAlloy of ENECON's METALCLAD family of products DurAlloy requires no heat, is machineable, trowelable, contains 100% solids, has unlimited shelf life (even when the packages are open), and is safe and simple to use. It may be difficult to accept but the repaired parts are even stronger than the original. It may be difficult to accept but the repaired parts are even stronger than the original.

At the bottom of the link (
DurAlloy) you see three videos of the actual application for 1) Machined Marine Tail Shaft Repair 2) Split Case Pump Repair & 3) in-place shaft repair.

The applications for the METALCLAD family are limitless (worn shafts, pumps, pipes (steam, heavy fuel, lub oil, MFO, seawater, etc.) condensers, cooler covers, cracked & holed casings, oversized bearing & bush housing, scored rams, sloppy keyways, stripped threads, warped, distorted or steam-cut flange faces, etc (sorry, not enough space). 

Call +357.97.900.449 or +357.22.1000.43 for additional information, to request a meeting or the products' MSDS/SDS or for free advice how ENECON can address your specific issue.